E1854EL

Array
Specifications
Documentation
Overall drawings
Related products

Type

Overall dimensions, mm, max

Weight, kg, max.

E1854EL

24 х 111 х 116

0.3

Input signal

0...0.5 A, 0...1 A, 0...2.5 A, 0...5 A,

0...125 V, 0...250 V, 0...500 V, 75...125 V, 150...250 V

Basic error limits

±0,5%

Temperature range (operating)

-40 °С... +50 °С

Protection extent

IP50

Installation

DIN-rail of 35 mm

Interface

RS485 (Мodbus RTU) – main, for data transmission

Data rate

4800, 9600, 19200, 38400 bit/s.

Parameters setting (reprogramming) through the interface

– digital output

– interface RS485 (Modbus RTU) parameters

– analogue output signal parameters

Analogue output (Accuracy class 0,5)

Quantity: 0, 1

Ranges: 0...5 mA; 0…20 mA; 4...20 mA

Digital output

DC voltage: 300 V; 100 mA

AC voltage: 200 V; 100 mA

Maximum input signal overload

150%, duration of 2 hours

Time of setting output analogue signal, max

0.5 s

Power supply

– 220 VU, 85...253 VAC,

– 50 Hz or 120...265 VDC

– 230 V, 85...253 VAC, 50 Hz

– 12 VN (12+6/-3) VDC

– 24 VN (24+12/-6) VDC

Power consumption from power circuit, max.

6.0 V•А

Calibration interval

8 years

Guarantee period

2 years

Mean life

20 years

Mean time between failures

200000 hours

E1854EL – а – b – с – d – f

a – input signal measurement ranges:

0...0.5 A, 0...1 A, 0...2.5 A, 0...5 A,

0...125 V, 0...250 V, 0...500 V, 75...125 V,

150...250 V

b – supply voltage:

220VU – universal power:

supply voltage of 85...253 VAC, 50 Hz or 120 ...265 VDC;

230 V – supply voltage of 85...253 VAC, 50 Hz;

12 VN – (12+6/-3) VDC;

24 VN – (24+12/-6) VDC

c – measurement range analogue output signal:

А = 0...5 mA; В = 4...20 mA; С = 0...20 mA;

х with the absence

d – digital output availability:

х – no output

01 – one digital output

f – custom design:

А – operation at NPP

(safety class – 4)

With the absence of custom design.

Ordering example

E1854EL – 0…2.5 A – 12 VN – В – 01 – А TU 25-7504.226-2014

For the transducer with the following characteristics: E1854EL transducer type, measurement range input signal of 0... 2.5 A, supply voltage of (12+6/-3) VDC, measurement range output signal of 4…20 mA, digital output, for operation at NPP (safety class 4).

Сertificate of conformity (jpg, 451.2 Kb )   View   Download
Manual (pdf, 1.2 Mb )   View   Download
Configurator (zip, 17.3 Mb )   View   Download


gabaryt_e1858el.jpg

Back to list