E856EL

Direct current and direct voltage measuring converters E856EL are intended for current and voltage measurement in one-phase DC circuits. The converters are used to control current and voltage of electrical systems and installations, for integrated automation of electric power industry facilities, APCS of energy-consuming facilities of different industry sectors, on marine vessels. The converters may be used for operation in the field of defense and safety. The possibility of data exchange through interface RS485 allows using The converters for digital data transmission to APCS. The converters may have a design without interface RS485.





Specifications
Documentation
Overall drawings
Related products

Type

Overall dimensions, mm, max

Weight, kg, max.

E856EL

with RS485

70 х 85.5 х 89

0.4

without RS485

70 х 86 х 80

0.5

Input signal

Output signal

Load resistance, max.

output 1

output 2

For the analogue output:

2,5 kΩ (0...5 mA,

0...2,5...5 mA);

2 kΩ (-5...0...5 mA);

0,5 kΩ (0...20 mA,

4...20 mA, 4...12...20mA,

0...10...20 mA)

0...5mA, 4...20mA,

0...20mA, -5...0...5mA

0...75mV,

-75...0...75mV, 0...60V,

0...100V, 0...150V,

0...250V

0...5mA, 0...20mA,

4...20mA, 0...2,5...5mA,

-5...0...5mA, 4...12...20mA,

0...10...20mA

0...5mA, 0...20mA,

4...20mA, 0...2,5...5mA,

4...12...20mA,

0...10...20mA,

-5...0...5mA

0...500V, 0...1000V

no

Basic error limits

±0,5%

A number of output signals

1 or 2

Temperature range (operating)

-40 °С... +50 °С

Power supply voltage

– 12 VN (12+6/-3) VDC

– 24 VN (24+12/-6) VDC

– 220 VU, 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC

– 230 V, 85...253 VAC, (50 ± 0.5) Hz

Galvanic isolation of input and output circuits, power circuits

Yes

Protection extent

IP50

Interface

RS485 (МodbusRTU), quantity: up to 2

– basic for data transmission

– additional for data transmission or connection of the display (Т44, Т54, Т74), Display panel (MI120, MI80)

Data rate

4800, 9600, 19200, 38400 baud.

Maximum input signal overload

120%, duration of 2 hours

Short-term overloads by input signal with ratio

2 (10 s); 7 (15 s); 10 (3 s); 20 (0.5 s) (from the rated current value)

1.5 (0.5 s) (from the rated voltage value)

Time of setting output analogue signal, max

0.5 s

Power consumption from power circuit, max.

6.0 V•А

Power consumption

by voltage circuits, max:

by current circuits, max:

1 W

0.01 W

Installation

DIN-rail 35 mm or directly on the panel

Calibration interval

10 years

Guarantee period

2 years

Mean life, min

15 years

Mean time between failures, min

100000 hours

Note: power supply and input signals are connected by terminal connectors “for screw” for wires of up to 4.0 mm2 in cross-section.

Order form

E856EL – а –b – с – d – e – f

a – input signal measurement ranges:

0...5 mA, 4...20 mA, 0...20 mA, -5...0...+5 mA

0...75 mV; -75...0...75 mV;

0...60 V; 0...100 V; 0...150 V; 0...250 V; 0...500 V;

0…1000 V

b – supply voltage:

12 VN (12+6/-3) VDC

24 VN (24+12/-6) VDC

220 VU from 85...253 VAC, (50 ± 0.5) Hz or 120...265 VDC

230 V from 85...253 VAC, (50 ± 0.5) Hz

c – measurement range analogue output signal:

А = 0...5 mA;

В = 4...20 mA;

С = 0...20 mA;

АР = 0...2.5...5 mA;

ВР = 4...12...20 mA;

СР = 0...10...20 mA;

ЕР = -5…0…+5 mA;

х with the absence

d – measurement range additional analogue output signal:

А = 0...5 mA;

В = 4...20 mA;

С = 0...20 mA;

АР = 0...2.5...5 mA;

ВР = 4...12...20 mA;

СР = 0...10...20 mA;

EP = -5...0...+5 mA

х with the absence

e – interface:

1 RS – one RS485 (main)

2RS – two RS485 (main and additional)

х – with the parameter absence

f – custom design:

А – operation at NPP

(safety class – 4);

ОМ2 – meters for marine application.

With the absence of custom design parameter is not specified.

Ordering example

E856EL – -75…0…75 mV – 24VN – АР – В – 2RS TU 25-7504.216-2011

E856EL transducer with the following characteristics: input signal measurement range -75...75 mV, supply voltage of (24+12/-6) VDC, measurement range analogue output signal of 0…2.5…5 mA, measurement range additional analogue output signal of 4...20 mA, two interfaces RS485.

Configurator (zip, 17.3 Mb )   View   Download
Сertificate of conformity ( об утв, 1.2 Mb )   View   Download
Manual (pdf, 1.8 Mb )   View   Download


E856EL (w/ RS485)

gabaryt_e856_RS.jpg
E856EL (w/o RS485)

gabaryt_e856.jpg

Back to list