Budgetary DC meter series

The meters are intended for measurement of current in chargers and other DC meters in different branches of industry in conditions of moderate climate.
To protect against contact with current-carrying rods, meters could be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.





Specifications
Documentation
Related products

Type

М42300.8

М42301.8

М4272.8

М4276.8

Overall dimension, mm

80х80

60х60

96х96

72х72

Panel cutout, mm

Ø 77.5

Ø 57.5

92х92

68х68

Scale length, mm

60

42

93

57

Basic error, %

± 4.0

± 4.0

± 4.0

± 4.0

Mass, kg

0.2

0.15

0.2

0.15

М42300.8, М42301.8, М4272.8, М4276.8

measurement range

connection method

operation conditions

А – 30; 50; 75; 100; 150; 300; 500;

750;

With outer shunt for 75 mV and calibrated wires of 0.035 Ω

IP40 – level of protection against environment effect.

Temperature -30...+50 °С, relative humidity 90 % at temperature +30 °С.

Vibration strength:

acceleration 5...30 m/s2,

frequency 10...70 Hz,

Impact resistance:

for М42300.8, М42301.8:

acceleration 100 m/s2, 2000 impacts;

for М4272.8, М4276.8:

acceleration 50 m/s2, 2000 impacts.

kА – 1.5; 3

The meters could be manufactured with other measurement limits.

М4272.8, М4276.8 Manual (zip, 1004 Kb )   View   Download
М42300.8, М42301.8 Manual (zip, 699.6 Kb )   View   Download