Meters with 60х60, 80х80 and 120х120 mm front frame

Panel AC and voltage meters are manufactured of two types:
– magnet-moving coil system with rectifier;
– electromagnetic system;
These meters allow current measuring within 25 µА...100 А and voltage 0.5 V...750 V with their direct switching on. To extend a measurement range: by current – current transformers type TOP-0.66 are used, by voltage – voltage transformers.
Ammeters and voltmeters are made with the zero-scale at the range edge. The meters can be made with any scales of any units of measurement according to Customer’s request.
For structural design, the AC meters are divided into two groups:
– meters with square front frames and round cases.
– meters with square front frames and square cases. The protection level for the front frame is IP50 or IP54, protection level for current-carrying rods – IP00.
To protect against contact with current-carrying rods, meters E42700, E42702 (ammeters up to 10 A, milliammeters, voltmeters, meters with actuation via current/voltage transformers), Ts42300, Ts42702 may be supplied with protective caps KZ-4. The need of supply shall be specified in case of order.





Specifications
Related products

Type

Ts42302

E42701

Ts42300

E42700

Ts42702

E42702

Overall dimension, mm

60х60

60х60

80х80

80х80

120х120

120х120

Panel cutout, mm

Ø57.5

Ø57.5

Ø77.5

Ø77.5

112х112

112х112

Scale length, mm, min.

44

44

65

65

90

90

Accuracy class

µА – 1.5; 2.5

А – 1.5; 2.5

2.5

А – 1.5; 2.5

1.5

1.5

mA. V – 2.5

V – 2.5

V – 2.5

Weight, kg, maximum

0.12

0.2

0.14

0.35

0.35

0.45

Ts42300, Ts42302


µA – 25*; 50; 100; 200; 300; 500

Directly

Temperature -30...+50 °С for mill- and microammeters. -50...+60 °С for voltmeters;

relative humidity 95 % at temperature 35 °С.

Standard frequency range is 45...1000 Hz.

Operating frequency range is 30-45..... 1000-20000 Hz for mill- and microammeters;

30-45..... 1000-10.000 Hz for voltmeters.

Vibration strength: acceleration 5...30 m/s2. frequency 10...70 Hz.

Impact resistance: acceleration 70 m/s2. frequency is 10...50 impacts per min.. 2000 impacts


mA – 1; 5; 10; 15; 10-30; 15-50;

30-100; 50-150; 100-300; 150-500; 300-1000


V – 0.5-3; 1-7.5; 2-15; 30; 50; 75; 150; 250; 300; 500; 600


* – for microammeter Ts42302 only


Ts42702


end value of a measurements range

transformation ratio

connection method

operation conditions

mA– 10; 20; 30; 50; 100;

250; 500


Directly

Temperature -40...+50 °С. relative humidity 95 % at temperature 35 °С.

Standard frequency range is 50...1000 Hz.

Vibration strength: acceleration 5 m/s2. frequency 20 Hz.

Vibration strength: acceleration 15 m/s2. frequency 30 Hz.

Impact resistance: acceleration 70 m/s2. frequency is 10...50 impacts per min.. 1000 impacts

V – 15; 30; 50; 75; 100; 150; 250; 300; 400; 500; 600


V – 450; 500; 600; 750

0-450V 380/100

0-500V 500/100

0-600V 500/100

0-750V 750/100

Via a voltage transformer with secondary voltage of 100 V

kV – 3.5; 4; 6; 7.5; 12.5; 15;

17.5; 20; 25; 40; 125; 150;

175; 200; 250; 400; 600

0...3.5kV 3000/100

0...4kV 4000/100

0...6kV 6000/100

0...7.5kV 6000/100

0...12.5kV 10000/100

0...15kV 13800/100

0...17.5kV 15750/100

0...20kV 18000/100

0...25kV 20000/100

0...40kV 35000/100

0...125kV 110000/100

0...150kV 150000/100

0...175kV 150000/100

0...200kV 200000/100

0...250kV 220000/100

0...400kV 330000/100

0...600kV 500000/100

E42702

measurement range

connection method

operation conditions

mA – 100; 250; 400; 600

Directly

Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.

Vibration strength: acceleration 5 m/s2, frequency 20 Hz.

Vibration strength: acceleration 15 m/s2, frequency 30 Hz.

Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.

Standard frequency and frequency range:

45-65; 50; 60; 200; 500; 1000 Hz

А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10; 20; 30; 50; 100*

А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800

Via a current transformer with secondary current of 1 or 5 A

kA – 1; 1.2; 1.5; 2; 3; 4; 5; 6; 8; 10; 20; 30; 40

E42702 – overload ammeter (overload factor – 2)

А – 1; 1.5; 2.5; 3; 4; 5; 6; 10; 15; 20; 30; 50; 100*

Directly

А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400

Via a current transformer with secondary current of 1 or 5 A

kA – 0.5; 0.6; 0.8; 1; 1.5; 2; 3; 4; 5; 6; 10; 20; 30; 40

E42702 – overload ammeter (overload factor – 5 or 6)

A – 1; 3; 5; 10

Directly

А – 1; 10

Via a current transformer with secondary current of 1 A

A – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150

Via a current transformer with secondary current of 5 A

kA – 0.2; 0.25; 0.3; 0.4; 0.5; 0.6; 0.75; 0.8; 1; 1.5; 2; 3; 4; 5; 6; 8; 10

* – for standard frequency and frequency range, Hz 45-55, 50.

E42700, E42701

mA* – 100; 250; 400; 600

Directly

Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.

Vibration strength: acceleration 5...30 m/s2, frequency 10...70 Hz.

Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.

Standard frequency and frequency range:

45-65; 50,180-550; 60; 180-550; 800;1000 Hz (for ammeters); 45-65; 50; 60; 200; 400;

500; 800; 1000 Hz (for voltmeters)

А – 1; 1.5; 2; 2.5; 3; 4; 5; 6; 10; 20; 30; 50; 100*

А – 5; 10; 15; 20; 30; 40; 50; 75; 80; 100; 150; 200; 250; 300; 400; 500; 600; 750; 800

Via a current transformer with secondary current of 1* or 5 A

kA – 1; 1.2;1.5; 2; 3; 4; 5; 6; 8; 10; 20; 30; 40

V – 10; 30; 50; 100; 150; 250; 400; 500; 600; 750

Directly

V – 400; 450; 500; 600; 750

Via a voltage transformer with secondary voltage of 100 V

kV* – 3.5; 4; 6; 7.5; 12.5; 15; 17.5; 20; 25; 40; 125; 150; 175; 200; 250; 400; 600

* – for E42700 only

For the meters E42700 with the upper limit of measurement range 100 A with direct actuation at standard frequency of 50 Hz and frequency range 45...65 Hz only.

For the meters E42700, E42701, E42702, Ts42702, the transformer primary current and voltage is the same as the upper limit of measurement range.

For voltmeter Ts42702, the transformer primary voltage is the same as data given in the table.

Note: ammeters E42700 may be manufactured with overload factor 2.

Meters manufacture is possible with other measurement ranges and for actuation via a current transformer with the secondary current of 1 A.

Ordering examples

Ammeter E42702, 20 А; 20/5, 50, v, TU 25-7504.133-2007

For ammeter E42702 manufactured for operation in conditions of moderate climate, with the upper measurement range 20 A, actuation via a current transformer with the secondary current of 5 A, vertical operating position, for standard frequency of 50 Hz.

The same is for an overload ammeter E42702 (overload factor – 5) with the upper value of the overload section of 100 A:

Ammeter E42702, 20...100 А; 20/5, 50, v, TU 25-7504.133-2007

The same is for an ammeter manufactured in the tropical conditions:

Ammeter E42702 Т3, 20...100 А; 20/5, 50, v, TU 25-7504.133-2007

For reference only:

v/g – vertical/horizontal operating position;

Б – dustproof and splashproof meter;

ОМ2 – meters for marine application.

Back to list