SchP00P, SchP01P, SchP02.01P

Small digital meters SchP00P, SchP01P, SchP02.01P are intended to measure and convert the effective value of current, voltage and frequency in one-phase electrical circuits and other AC circuits into output unified DC signals and to transmit measured values through serial digital interface RS485.
The meters are single-channel and single-scale meters with designs by overall dimensions, measurement ranges, indication ranges, supply voltage, availability of interface, digital and analogue outputs, indicators colour, accuracy class, custom design.
One-phase meters can be used in three-phase electrical circuits for measurement and conversion of parameters of one phase.
The meters could be used complete with primary transducers for measurement non-electrical values if ranges of output electrical signal of primary transducers corresponds to the meters  input signal ranges.
The meters are used in the energy industry and other sectors of industry for control of electrical parameters.





Specifications
Documentation
Overall drawings
Related products

Type

Overall dimensions, mm

Sign height, mm

Weight, kg, maximum

SchP00P

48 × 24 × 90

9.9

0.2

SchP01P

96 × 24 × 90

9.9

0.2

SchP02.01P

96 × 48 × 90

20

0.3

Accuracy class

– when measuring AC intensity and voltage – 0.2 or 0.5;

– when measuring input signal frequency – 0.05;

– when converting – 0.5.

Temperature range (operating)

-40 °С…+50 °С

Maximum indication range

0... plus 9999

Frequency range measured/converted signals

45 ... 65 Hz (by default),

300 ... 500 Hz (optionally, when ordering)

Number of measuring channels

1

Number of displayed parameters

1 or 2 (the 2nd one for display of input signal frequency, sequential display)

Galvanic isolation of input and output circuits, power circuits

The meters have galvanic isolation in the power circuit, output circuits (SchP00P meters have no galvanic isolation in interface RS circuit)

Protection extent on the front frame

IP50

Interface RS485 (protocol Modbus RTU)

Quantity: 0 or 1

Interface exchange rate

9600, 19200, 38400, 57600 bit/s.

Analogue output (accuracy class 0.5)

Quantity: 0, 1, 2

Ranges: 0...5 mA, 4…20 mA, 0...20 mA,

0…2.5…5 mA, 4…12…20 mA, 0…10…20 mA

Load resistance, kΩ

0.5 (for 4...20 mA, 0...20 mA, 4…12…20 mA, 0…10…20 mA)

2.5 (for 0...5 mA, 0…2.5…5 mA)

Digital output

Quantity: 0; 1; 2;

DC voltage 300 V, 100 mA or

AC voltage 200 V, 100 mA

Maximum permissible input signal overload

150%

Time of setting output analogue signal, max

0.5 s

Input resistance at voltage measurement, min.

(1±0.005) MΩ

Power supply

– 5 V (5±0.25) VDC,

– 12 V (12±0.6) VDC,

– 24 V (24±1.2) VDC,

– 5 VN (5+4/-0.5) VDC,

– 12 VN (12+6/-3) VDC,

– 24 VN (24+12/-6) VDC

– outer unit of balanced power supply of 5 V (for SchP00P)

Power consumption, max

SchP00P – 1.7 VA; SchP01P – 2.7 VA; SchP02.01P – 3.2 VA

Calibration interval

10 years

Guarantee period

36 months

Mean life, min

20 years

Mean time between failures

200 000 h

Order form

SchPa – b – с – d – e – f – g – h

SchPа – meter type (by the Overall dimension, mm):

SchP00P – 48×24,

SchP01P – 96×24,

SchP02.01P – 96×48,

b – reference designation of input signal measurement range:

mV: 100; 150; 200; 250; 500; 1000; 2000

V: 1; 2; 5; 10; 20; 50; 100; 150; 200; 250;

380 (except for SchP00P); 500 (except for SchP00P);

750 (except for SchP00P, SchP01P)

mA: 2; 5; 10; 20; 50; 100; 200; 500; 1000; 2000

А: 1; 2; 5

By default, frequency range input signal is 45...65 Hz (when ordering, it is not specified).

When ordering the meter with input signal frequency range 300…500 Hz, specify reference designation 400 Hz in parameter b in brackets.

Note: if the indication range differs from the measurement range the input signal and from the transformation factor, give additionally the ordered indication range in the note to the order formula.

c – reference designation of supply voltage:

5V, 12V, 24V, 5VN, 12VN, 24VN;

× – with outer unit of balanced power supply of 5 V (for SchP00P);

d – availability of interface RS485:

1RS – one interface,

× – no interface;

e – reference designation of analogue and digital outputs:

01 – one digital outputs without analogue outputs,

10 – one analogue output without digital input,

11 – one analogue and one digital output,

12 – one analogue and two digital outputs,

20 – two analogue outputs without digital ones,

22 – two analogue and two digital outputs,

× – no analogue and digital outputs

Note – reference designation of analogue output is specified after figures in brackets: А – 0...5 mA, В – 4...20 mA, С – 0...20 mA,

АР – 0…2.5…5 mA, ВР – 4…12…20 mA, СР – 0…10…20 mA, when ordering two analogue outputs, specify it separated by a comma;

f – indicators colour:

R – red, G – green, Y – yellow;

g – accuracy class:

0.2 or 0.5;

h – custom design:

А – for operation at NPP (safety class 4),

– with the absence of custom design parameter is not specified.

SchPa meter type

Full reference designation code parameter

b1

с

d

е

f

g

h

SchP00P

b1

х, 5V, 12V, 24V

х, 1RS

X

+

+

+

SchP01P

b1

5V, 12V, 24V

х, 1RS

х,01,10,11

+

+

+

SchP02.01P

b1

5VN, 12VN, 24VN

1RS

х, 12,20,22

+

+

+

Notes

Sign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available in the order formula.

Unused parameter h is not specified.

For SchP00P meter, interface RS485 without galvanic isolation.

Ordering examples

SchP00P – 10kV/100V – × – × – × – R – 0.5, TU 25-7504.228-2015

For SchP00P meter, transformation factor of 10 kV/100 V with outer unit of balanced power supply of 5 V without interface, analogue and digital outputs; red indicators, accuracy class 0.5.

SchP01P – 100mA – 24V – 1RS – × – R – 0.5 – А, TU 25-7504.228-2015

For SchP01P meter, input signal measurement range 0...100 mA, supply voltage of 24 VDC (balanced), one interface RS485, without analogue and digital outputs, red indicators, accuracy class 0.5, custom design A, indication range 0...50 m.

Сertificate of conformity (jpg, 427.8 Kb )   View   Download
Manual (pdf, 3.8 Mb )   View   Download
Configurator (zip, 17.3 Mb )   View   Download


SchP00P
gabaryt_shp_en.jpg

SchP01P
gabaryt_shp_en_2.jpg

SchP02.01P
gabaryt_shp_en_3.jpg

Back to list