Sch02P, Sch72P, Sch96P, Sch120P
|
Type |
Overall dimensions, mm |
Panel cutout, mm |
Sign height, mm |
Weight, kg, max. |
|
Sch02P |
96 х 48 х 122 |
90 х 42 |
14 |
0.4 |
|
Sch72P |
72 х 72 х 76 |
68 х 68 |
10 |
0.2 |
|
Sch96P |
96 х 96 х 76 |
92 х 92 |
14 |
0.5 |
|
Sch120P |
120 х 120 х 76 |
112 х 112 |
20 |
0.5 |
|
Accuracy class |
0.1 or 0.2 |
|
Rated voltage |
mV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000 V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 500, 750 |
|
Rated current |
mA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000 А: 1, 2 |
|
Temperature range (operating) |
-40 °С... +70 °С UKhL3.1 |
|
Maximum indication range |
-19999...+19999 |
|
Number of measuring channels |
1 |
|
Galvanic isolation of input and output circuits, power circuits |
Yes |
|
Front frame protection level |
IP50 |
|
Interface RS485 (protocol Modbus RTU) |
– basic for data transmission – additional for data transmission or connection of the display and indication modules (MI120, MI80) |
|
Interface exchange rate |
4600, 9600, 19200, 38400 bit/s. |
|
Analogue output (accuracy class 0.5) |
Quantity: 0; 1; 2; Ranges: 0...5 mA, 4...20 mA, 0…20 mA, 0...2.5...5 mA; 4...12...20 mA; 0…10…20 mA |
|
Load resistance |
2.5 kΩ for ranges of 0...5 mA, 0...2.5...5 mA; 0.5 kΩ for ranges of 0...20 mA, 4...20 mA, 4...12...20 mA, 0…10…20 mA |
|
Digital output |
Quantity: 0; 1; 2; DC voltage 300 V, 100 mA or AC voltage 200 V, 100 mA |
|
Maximum permissible input signal overload (from the upper limit of the measurement range)* |
150% (1 minute) |
|
Time of setting output analogue signal, max |
1.0 s |
|
Input resistance at load voltage measurement, min. |
1 MΩ |
|
Power supply parameters |
– 5 VN (5+4/-0.5) VDC, – 12 VN (12+6/-3) VDC, – 24 VN (24+12/-6) VDC, – 220 VU of 85...253 VAC, (50 ± 0.5) Hz or 120 ... 265 VDC – 230 V from 85...253 VAC, (50 ± 0.5) Hz |
|
Power consumption, max |
6 V•А |
|
Calibration interval |
6 years |
|
Guarantee period |
36 months |
|
Mean life |
30 years |
|
Mean time between failures |
150000 |
|
Note: it is possible to connect the outer circuits according to the designation of connector contacts to the terminals “for screw” using a cord of up to 4 mm2 in cross-section, multi-core wires of up to 2.5 mm2. When connecting supply DC voltage of 120...265 V at supply voltage of 220 VU to power contacts “L”, “N”, any polarity is possible. * Maximum input signal overload (from the rated value of the measurement range) 130% (2 hours). |
|
Order form
Sch а – b – c – d – е – f – g – h
Sch – meter type (by the Overall dimension, mm):
Sch02P – 96×48,
Sch72P – 72×72,
Sch96P – 96×96,
Sch120P – 120×120,
b – measurement range for the input signal with direct connection or transformation factor with connection through the outside shunt
mV: 60, 75, 100, 150, 200, 250, 500, 1000, 2000
V: 1, 2, 5, 10, 2…10, 20, 50, 100, 150, 200, 250, 500, 750
mA: 2, 5, 10, 20, 4…20, 50, 100, 200, 500, 1000
А: 1, 2
Note: if the indication range differs from the measurement range the input signal and from the shunt conversion factor, give additionally the ordered indication range in the note to the order formula.
c – reference designation of supply voltage:
5 VN, 12 VN, 24 VN, 220 VU, 230 V
d – availability of interfaces RS485:
1RS – one interface,
2RS – two interfaces,
х – with the absence of parameter (for Sch120P only)
e – reference designation of analogue and digital outputs:
02 – two digital outputs without analogue output,
11 – one analogue and one digital output,
12 – one analogue and two digital outputs,
20 – two analogue outputs without digital ones,
22 – two analogue and two digital outputs,
х – without analogue and digital outputs
Note: the reference designation of analogue output is specified after figures in brackets: А = 0...5 mA, В = 4...20 mA, С = 0...20 mA,
АР = 0…2.5…5 mA, ВР = 4…12…20 mA, СР = 0…10…20 mA,
when ordering two analogue outputs, specify it separated by a comma.
f – indicators colour:
R – red, G – green, Y – yellow
g – accuracy class: 0.1 or 0.2
h – special design:
ОМ2 – meters for marine application,
А – for operation at NPP (safety class 4), do not specify in other cases.
|
Type |
Full reference designation code parameter |
||||||
|
b |
с |
d |
e |
f |
g |
h* |
|
|
Sch02P |
+ |
+ |
1RS |
х, 12, 20, 22 |
+ |
+ |
+ |
|
Sch72P |
+ |
+ |
1RS |
х, 02, 11, 20 |
+ |
+ |
+ |
|
Sch96P |
+ |
+ |
1RS, 2RS |
х, 12, 20, 22 |
+ |
+ |
+ |
|
Sch120P |
+ |
+ |
х,1RS, 2RS |
х, 12, 20, 22 |
+ |
+ |
+ |
|
* For the meters with special design, accuracy class 0.2. Notes Sign “+” means that availability of all possible versions of a parameter in the order formula. Sign “x” means that no parameter is available in the order formula. |
|||||||
Ordering example
Sch120P – 100 V – 220 V – 2 RS – 22(А,С) – R – 0.2 TU 25-7504.218-2012
Note: indication range -20…+50 °С
For Sch120P meter, measurement range minus 100 to plus 100 V, supply voltage of 85...253 VAC, 50 Hz or 120...265 VDC, two interfaces RS485, two analogue outputs 0…5 mA and 0…20 mA, two digital output, red indicators, accuracy class 0.2, indication range -20…+50 °С.