DC and voltage meters M42300, M42301, M42303, M42304, M42305, M42306, M4264М, M4265М
|
Type |
М42303 М42306 |
М42301 М42305 |
М42300 М42304 |
М4264М М4265М |
|
Front frame dimension, mm |
40х40 |
60х60 |
80х80 |
120х120 |
|
Panel cutout, mm |
Ø37.5 |
Ø57.5 |
Ø77.5 |
112х112 |
|
Scale length, mm, min. |
26 |
36 |
56 |
95 |
|
Accuracy class |
2.5; 4.0 |
1.5; 2.5 |
1.5; 2.5 |
1.5; 2.5* |
|
Weight, kg, maximum |
0.08 |
0.15 |
0.2 |
0.35 |
|
* – for М4265М only |
||||
|
М42300, М42301, М42303 |
||
|
measurement range |
actuation mode |
operation conditions |
|
μA – 100; 150*; 200; 300; 500; 1000 |
Directly
|
Temperature -50...+60 °С relative humidity 95 % at temperature +35 °С. Resistance to vibration: acceleration 5...30 m/s2, frequency 10...70 Hz. Resistance to shock: acceleration 100 m/s2, 2000 shocks with frequency 80...120 shocks per min. For meters with advanced resistance to mechanical effects: temperature -50...+60 °С relative humidity 95 % at temperature of +40 °С. Resistance to vibration: acceleration 2...20 m/s2, frequency 10...40 Hz. Resistance to shock: 100 m/s2 – 88,000 shocks 150 m/s2 – 20,000 shocks 750 m/s2 – 2000 shocks with frequency 80...120 shocks per minute |
|
mA – 0.5**; 1; 2.5-0-2.5**; 5; 10; 15; 20; 30; 50; 100; 150; 300; 500; 600; 3/30*; 3/50*; 5/50*; 30/600** |
||
|
mA – 50 mA/20 V** |
||
|
А – 1; 2; 3; 5; 10; 15* |
||
|
А – 15***; 20; 30; 50; 75; 100; 150; 200; 300; 500; 750; 200-0-750 |
With outer shunt for 75 mV and calibrated wires of 0.035 Ω |
|
|
kA – 1; 1.5; 2; 4; 6 |
||
|
V – 0.075* |
With calibrated wires of 0.035 Ω |
|
|
V – 1*;2; 3; 7.5; 10; 15; 20; 30; 50; 75; 100; 150; 250; 300; 500; 600; 3/30*; 3/300*; 30/300*; 4/100*; 7.5/300*; 8/300*; 10/100*; 15/150*; 15/300*; 20/40*; 0.3/15-0-0.3/15* |
Directly |
|
|
V** – 0.075/9; 2.5/10; 3/100; 3/300; 10/300; 30/300; 6; 25; 400 |
||
|
V – 150/1500*; 15/150/1500* |
With outer additional resistance at rated current of 5 mA |
|
|
kV – 1; 1.5; 3 |
||
|
* – for meters М42300 and М42301 only ** – for meters М42303 only *** – for meters М42300 only |
||
|
М42304, М42305, М42306 |
||
|
measurement range |
actuation mode |
operation conditions |
|
μA – 5*; 10; 20; 25*; 30 |
Directly |
Temperature -30...+50 °С, relative humidity 95 % at temperature +35 °С. Resistance to vibration: acceleration 5 m/s2, frequency 50 Hz. Resistance to shock: acceleration 30 m/s2, frequency of shocks 10...50 Hz per min., 2000 shocks. |
|
μA – 50 |
Directly |
Temperature -50...+60 °С, relative humidity 95 % at temperature +35 °С. Resistance to vibration: acceleration 5...30 m/s2, frequency 10...70 Hz. Resistance to shock: acceleration 100 m/s2, frequency of shocks 10...50 Hz per min., 2000 shocks. For meters with advanced resistance to mechanical effects: temperature -50...+60 °С, relative humidity 95 % at temperature +40 °С. Resistance to vibration: acceleration 2...20 m/s2, frequency 10...40 Hz. Resistance to shock: 100 m/s2 – 88,000 shocks, 150 m/s2 – 20,000 shocks, 500 m/s2 – 2000 shocks with frequency 80...120 shocks per minute. |
|
mV – 25**; 50; 75; 150; 300; 500; 750; 1000 |
With calibrated wires of 0.035 Ω |
|
|
* – with the zero mark inside the measurement range only ** – М42304, М42305 – for accuracy class 2.5 only; М42306 – for accuracy class 4.0 only |
||
|
М4264М |
||
|
measurement range |
actuation mode |
operation conditions |
|
mA– 0.5; 0.75; 1; 3; 5; 10; 15; 20; 30; 50; 75; 100; 150; 300; 500; 600 |
Directly |
Temperature -40...+50 °С relative humidity 95 % at temperature +35 °С. Resistance to vibration: acceleration 15 m/s2, frequency 30 Hz. Resistance to shock: acceleration 70 m/s2 – 1000 shocks, frequency 10...50 shocks per minute. Resistance to vibration: acceleration 5 m/s2, Frequency 20 Hz – for М4264М |
|
A – 1; 2; 3; 5; 10; 20 |
||
|
A – 30; 50; 75; 100; 150; 200; 300; 500; 750 |
With outer shunt for 75 mV and calibrated wires of 0.035 Ω |
|
|
kA – 1; 1.5; 2; 3; 4; 5; 6; 7.5 |
||
|
A – 200; 400; 600 |
With outer shunt for 150 mV and calibrated wires |
|
|
kA – 1; 2; 3; 4; 6; 8; 10; 15; 20; 30 |
||
|
V – 0.075*; 0.15*; 3; 7.5; 15; 30; 50; 75; 100; 150; 250; 300; 400; 500; 600; 750 |
Directly |
|
|
kV – 1; 1.5; 3; 10; 15 |
With outer additional resistance at rated current of 5 mA |
|
|
М4265М |
||
|
μA – 50**; 100; 200; 300; 500; 750; 1000 |
Directly |
|
|
mV – 25**; 50; 75; 150; 300; 500; 750; 1000 |
With calibrated wires of 0.035 Ω |
|
|
* – with calibrated wires of 0.035 Ω ** – with the zero mark inside the measurement range only |
||
Ordering example
Voltmeter М42300, 0-30 V, 1.5, vert, Б, (m), TU 25-7504.132-2007
For voltmeter М42300 with measurement range of 0...30 V, accuracy class 1.5, vertical position, dust-splash-proof design with advanced mechanical characteristics.
Voltmeter М42303, 50-0-50 V, 1.5, vert, TU 25-7504.132-2007
For voltmeter М42303 with measurement range of 50-0-50 V, accuracy class 1.5, vertical position.
Voltmeter М42303 Т3, 50-0-50 V, 1.5, v, TU 25-7504.132-2007
For voltmeter М42303 manufactured for operation in tropical conditions, with measurement range of 50-0-50 V, accuracy class 1.5, vertical position.
Milliampremeter М42300.х, 5-0-5 mA, scale 100-0-100%, 1.5, v, TU 25-7504.132-2007
For milliammeter М42300, special design Х, with rated current of 5 mA, scale 100-0-100%, accuracy class 1.5, the standard position is vertical.
For devices with special marks, inscriptions, special scale graduation as per the Customer’s data, a letter of the relative meter design is added to a meter type after point.
For reference only:
v/g – vertical/horizontal position;
Б – dust-drop-proof design;
(m) – advanced mechanical characteristics of operation;
Т3 – for operation in the tropical conditions;
ОМ2 – for operation on marine vessels (М42300, М42301, М42303, М4264М)